Cristin-resultat-ID: 1548953
Sist endret: 23. januar 2018, 21:33
NVI-rapporteringsår: 2017
Resultat
Vitenskapelig artikkel
2017

Ultrasound enhanced CO2 Stripping from Lean MEA Solution at Pressures from 1 to 2.5 bar(a)

Bidragsytere:
  • Jiru Ying
  • Willem Haverkort
  • Dag-Arne Eimer og
  • Hans Aksel Haugen

Tidsskrift

Energy Procedia
ISSN 1876-6102
e-ISSN 1876-6102
NVI-nivå 0

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2017
Publisert online: 2017
Trykket: 2017
Volum: 114
Sider: 139 - 148

Beskrivelse Beskrivelse

Tittel

Ultrasound enhanced CO2 Stripping from Lean MEA Solution at Pressures from 1 to 2.5 bar(a)

Sammendrag

Ultrasound was introduced to assist CO2 stripping from lean 30 wt% MEA aqueous solutions in a reboiler. The effect of ultrasound on CO2 stripping was investigated at 2.5 bar(a) under two pressure control methods, solenoid operated on/off valve (OOV) and manual needle valve (NV) method. The results show that the CO2 stripping rate can be improved significantly when ultrasound is introduced. This is particularly so at higher pressures for which the driving temperature difference with the steam is smallest A reduction in pressure obviously also has a strong effect on CO2 stripping.

Bidragsytere

Jiru Ying

  • Tilknyttet:
    Forfatter
    ved Prosessteknologi ved SINTEF AS

Willem Haverkort

  • Tilknyttet:
    Forfatter
    ved Shell

Dag-Arne Eimer

  • Tilknyttet:
    Forfatter
    ved Prosessteknologi ved SINTEF AS

Hans Aksel Haugen

  • Tilknyttet:
    Forfatter
    ved Prosessteknologi ved SINTEF AS
1 - 4 av 4