Resultat
Vitenskapelig artikkel
2020

Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures

Bidragsytere:
  • Kaare Sourin Midtgaard
  • Endre Søreide
  • Jan Egil Brattgjerd
  • Gilbert Moatshe
  • Jan Erik Madsen og
  • Gunnar B Flugsrud

Tidsskrift

Journal of shoulder and elbow surgery
ISSN 1058-2746
e-ISSN 1532-6500
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2020
Volum: 29
Hefte: 6
Sider: 1242 - 1248
Open Access

Importkilder

Scopus-ID: 2-s2.0-85080908886

Beskrivelse Beskrivelse

Tittel

Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures

Sammendrag

Background: Tension band wiring (TBW) is the standard method for treating transverse olecranon fractures, but high rates of complications and reoperations have been reported. Plate fixation (PF) with locking screws has been introduced as an alternative method that may retain the fracture reduction better with a higher load to failure. Methods: Twenty paired cadaveric elbows were used. All soft tissues except for the triceps tendon were removed. A standardized transverse fracture was created, and each pair was allocated randomly to TBW or PF with locking screws. The triceps tendon was mounted to the materials testing machine with the elbow in 90° of flexion. Construct stiffness was compared 3 times. Then, the elbows underwent a chair lift-off test by loading the triceps tendon to 300 N for 500 cycles. Finally, a load-to-failure test was performed, and failure mechanism was recorded. Results: The construct stiffness of PF was higher in the first of 3 measurements. No difference was observed in the cyclic test or in load to failure. Hardware failure was the failure mechanism in 8 of 10 TBW constructs, and all failures occurred directly under the twists of the metal wire. Hardware failure was the cause of failure in only 1 elbow in the PF group (P

Bidragsytere

Kaare Sourin Midtgaard

  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling - Ullevål ved Universitetet i Oslo
  • Tilknyttet:
    Forfatter
    ved Forsvarets sanitet
  • Tilknyttet:
    Forfatter
    ved Klinikk for ortopedi ved Oslo universitetssykehus HF

Endre Søreide

  • Tilknyttet:
    Forfatter
    ved Klinikk for ortopedi ved Oslo universitetssykehus HF
  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling - Ullevål ved Universitetet i Oslo

Jan Egil Brattgjerd

  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling ved Oslo universitetssykehus HF
  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling - Ullevål ved Universitetet i Oslo

Gilbert Moatshe

  • Tilknyttet:
    Forfatter
    ved Klinikk for ortopedi ved Oslo universitetssykehus HF
  • Tilknyttet:
    Forfatter
    ved Institutt for idrettsmedisinske fag ved Norges idrettshøgskole

Jan Erik Madsen

  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling ved Oslo universitetssykehus HF
  • Tilknyttet:
    Forfatter
    ved Ortopedisk avdeling - Ullevål ved Universitetet i Oslo
1 - 5 av 6 | Neste | Siste »