Cristin-resultat-ID: 1237169
Sist endret: 18. juni 2015, 12:18
NVI-rapporteringsår: 2015
Resultat
Vitenskapelig artikkel
2015

Stability investigation of micro-configured Pd-Ag membrane modules - Effect of operating temperature and pressure

Bidragsytere:
  • Thijs Peters
  • Marit Synnøve Sæverud Stange
  • Martin Fleissner Sunding og
  • Rune Bredesen

Tidsskrift

International Journal of Hydrogen Energy
ISSN 0360-3199
e-ISSN 1879-3487
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2015
Volum: 40
Hefte: 8
Sider: 3497 - 3505
Open Access

Importkilder

Scopus-ID: 2-s2.0-84922927723

Beskrivelse Beskrivelse

Tittel

Stability investigation of micro-configured Pd-Ag membrane modules - Effect of operating temperature and pressure

Sammendrag

The long-term stability over a period of up to 50 days has been reported for various designs of microstructured Pd77Ag23 membrane modules for H2 production and purification. Even though microchannels provide sufficient mechanical support for moderate trans-membrane pressure difference and temperatures, i.e., 4–5 bars and 400–450 °C, long-term operation under these operating conditions results in a large deformative settling of the Pd77Ag23 film into the microchannel support. This settling leads to microstructural changes and pore formation on the feed surface of the membrane film that ultimately results in membrane failure. For pressures above approximately 5 bars, the application of microchannel-supported modules is thus not feasible, and for that purpose a continuous porous stainless steel support is introduced that allows for a sufficient stabilisation of the thin Pd77Ag23 films. For such a porous stainless steel supported microchannel module, a hydrogen flux of 195.3 mL cm−2 min−1 is obtained at 450 °C and 5 bars feed pressure, corresponding to a permeability of 3.4·10−8 mol m−1 s−1 Pa−0.5. During the complete operation of 1100 h at 450 °C, the module shows a very good stability up to the highest feed pressure applied of 15 bars. The N2 leakage flux has remained below the detection limit of the equipment, 5 μL cm−2 min−1, resulting in a minimum value for the H2/N2 permselectivity of 39.000 applying the pure H2 flux value obtained at 5 bars.

Bidragsytere

Thijs Peters

  • Tilknyttet:
    Forfatter
    ved Bærekraftig energiteknologi ved SINTEF AS

Marit Synnøve Sæverud Stange

  • Tilknyttet:
    Forfatter
    ved Bærekraftig energiteknologi ved SINTEF AS

Martin Fleissner Sunding

  • Tilknyttet:
    Forfatter
    ved Bærekraftig energiteknologi ved SINTEF AS

Rune Bredesen

  • Tilknyttet:
    Forfatter
    ved Bærekraftig energiteknologi ved SINTEF AS
1 - 4 av 4