Evaluation of Simplified Space-Heating Hydronic Distribution for Norwegian Passive Houses

Bidragsytere:
  • Laurent Georges
  • Maria Justo Alonso
  • Ruth Woods
  • Kang Wen
  • Fredrik Håheim
  • Peng Liu
  • mfl.

Utgiver/serie

Utgiver

SINTEF akademisk forlag
NVI-nivå 0

Serie

ZEB Project report
ISSN 1893-157X

Om resultatet

Rapport
Publiseringsår: 2017
Hefte: 39
Antall sider: 118
ISBN: 978-82-536-1558-5
Open Access

Klassifisering

Emneord

Termisk komfort • Passivhus • Forenkling • Radiator

Beskrivelse Beskrivelse

Tittel

Evaluation of Simplified Space-Heating Hydronic Distribution for Norwegian Passive Houses

Sammendrag

This technical report combines research results from the Norwegian Research Center on Zero Emission Buildings (ZEB) and a competence project about simplified hydronic distribution funded by Husbanken. In the Norwegian definition of the passive house standard (NS3700), the current building code TEK10 or existing concepts of ZEB residential buildings, building envelopes are so-called super-insulated in order to drastically reduce the space-heating needs. Given this high level of insulation, it is theoretically possible to simplify the space-heating distribution inside the building by reducing the number of heat emitters. There is currently a lack of theoretical knowledge about the design of simplified distribution systems and lack of evidence-based feedbacks about their actual performance during real operation. The present work investigates the performance of simplified space-heating distribution in superinsulated residential buildings using one radiator per floor. The case with less than one heat emitter per floor is not considered here. In all investigated cases, the building was equipped with balanced mechanical ventilation with one centralized heat recovery and one set-point temperature for the supply ventilation air (sometimes called one-zone mechanical ventilation). In other words, all the supply ventilation air is preheated at the same temperature, without distinction between rooms. The research methodology is based on field and laboratory measurements, calibrated detailed dynamic simulations (using IDA-ICE) as well as user’s interviews. The main research question was to investigate the real, desired and perceived thermal environment in heated areas (like the living room) and in the rooms without radiators (like bedrooms). In this context, the question of window openings in bedrooms was also addressed. The research also investigated the user behavior, such as the way users operate the heating system in reality. In addition...

Bidragsytere

Laurent Francis Ghislain Georges

Bidragsyterens navn vises på dette resultatet som Laurent Georges
  • Tilknyttet:
    Forfatter
    ved Institutt for energi- og prosessteknikk ved Norges teknisk-naturvitenskapelige universitet

Maria Justo Alonso

  • Tilknyttet:
    Forfatter
    ved Arkitektur, byggematerialer og konstruksjoner ved SINTEF AS

Ruth Woods

  • Tilknyttet:
    Forfatter
    ved Arkitektur, byggematerialer og konstruksjoner ved SINTEF AS

Kang Wen

  • Tilknyttet:
    Forfatter
    ved Norges teknisk-naturvitenskapelige universitet
  • Tilknyttet:
    Forfatter
    ved Kina

Fredrik Håheim

  • Tilknyttet:
    Forfatter
    ved Norges teknisk-naturvitenskapelige universitet
1 - 5 av 8 | Neste | Siste »