Cristin-resultat-ID: 1817654
Sist endret: 29. juni 2020, 15:29
Resultat
Rapport
2020

Sammenlignende laboratorieprøvninger (SLP) – Analyse av ferskvann. SLP 20-28

Bidragsytere:
  • Tina Bryntesen

Utgiver/serie

Utgiver

Norsk institutt for vannforskning

Serie

NIVA-rapport
ISSN 1894-7948

Om resultatet

Rapport
Publiseringsår: 2020
Hefte: 7510
Antall sider: 88
ISBN: 978-82-577-7245-1
Open Access

Klassifisering

Vitenskapsdisipliner

Matematikk og naturvitenskap

Emneord

Ferskvannsanalyse • SLP • Prestasjonsprøving • Akkreditering

Beskrivelse Beskrivelse

Tittel

Sammenlignende laboratorieprøvninger (SLP) – Analyse av ferskvann. SLP 20-28

Sammendrag

Under en sammenliknende laboratorieprøving (SLP) gjennomført i januar – april 2020 bestemte 40 laboratorier pH, konduktivitet, turbiditet, farge, UV-absorpsjon, natrium, kalium, kalsium, magnesium, hardhet, alkalitet, klorid, sulfat, fluorid, totalt organisk karbon, kjemisk oksygenforbruk (CODMn), fosfat, totalfosfor, ammonium, nitrat, totalnitrogen, aluminium, bly, jern, kadmium, kobber, krom, mangan, nikkel, sink, antimon og arsen i vann. Det var påmeldt 42 deltakere, men 2 av disse fikk ikke rapportert resultater før rapporteringsfristen. Prøvene ble laget ved å tilsette kjente stoffmengder til vann fra Kvisla og Viksjøen i Aurskog-Høland kommune. Vannet var på forhånd filtrert gjennom membranfilter med porevidde 0,45 μm. Totalt ble 85 % av resultatene vurdert som akseptable, en andel som er på nivå med de seneste årene. Best resultater viser konduktivitet, farge, kalium, klorid, jern og mangan, ≥ 95 % akseptable resultater. Det svakeste resultatet ble observert for ammonium, som hadde 38 % akseptable resultater. Enkelte av parameterne opptrådte i lave konsentrasjoner og laboratoriene må ta hensyn til usikkerheten i "sann verdi" ved evalueringen av sine resultater. Det er stor variasjon i analysekvaliteten mellom laboratoriene, og de som har avvikende resultater bør snarest vurdere disse resultater opp mot egne oppgitte analyseusikkerheter for de aktuelle analysene, og deretter eventuelt igangsette tiltak for å forbedre kvaliteten på bestemmelsene.

Tittel

Interlaboratory comparison – Analysis of freshwater

Sammendrag

The 28th Norwegian intercomparison study for analysis of fresh water, designated 20-28, was organized in January – April 2020 with 42 participants. Two of the participants were unable to report results in time for the deadline. The study comprised analysis of three sample sets of four samples (A-D, E-H, I-L), and two sample sets of two samples (M-N and O-P), made by adding known amounts of stoichiometric material to water from Kvisla and Viksjøen in Aurskog-Høland municipality, which had been filtered through membrane filter with pore size 0,45 μm. The program included 32 different parameters: pH, conductivity, turbidity, colour, UV-absorption, sodium, potassium, calcium, magnesium, hardness, alkalinity, chloride, sulfate, fluoride, total organic carbon, chemical oxygen demand (CODMn), phosphate, total phosphorus, ammonium, nitrate, total nitrogen, aluminium, lead, iron, cadmium, copper, chromium, manganese, nickel, zinc, antimony and arsenic. The analysis was largely carried out according to Norwegian standards or equivalent methods (Table B1). The median of the participants' results, after outliers have been omitted, is selected as the "true" value. The acceptance limit is normally set to ± 20 % of the average true value for the two samples that form a pair. The results are presented graphically in a Youden diagram, where a circle with the acceptance limit as radius is drawn. The result pairs within the circle are affected by a total error less than the limit and are hence considered acceptable (Appendix A). In total 85 % of participants' results were acceptable, a result which is comparable to the latest intercomparison studies (Table 1). 20 parameters had acceptable results above 80 %. 8 parameters had 70-79 %, 2 had 60-69 % and the final 2 had 50% or less acceptable results. Some laboratories' results are dominated by large systematic or random deviations. As in previous intercomparison studies, some results have been reported in the wrong unit of measurement. This shows how all parts of the chain of analysis needs to have quality control if reliable data are to be achieved. Systematic deviations are particularly prominent in some instrumental analyses. In these cases, the goal of the troubleshooting should be to clarify whether the error is constant and/or dependent on the concentration, to obtain an indication of what the cause of the error could be (Appendix A). In some cases, the analysis methods haven't been sufficiently sensitive for the concentration level of the analytes. When considering their results, laboratories must consider the low level of concentration of analytes in some of the samples. Internal quality control [Hovind et al. 2006] is necessary for the running evaluation of the laboratories' own methods and routines. If possible, the accuracy of the results should be controlled by certified reference materials (CRM's), or alternatively by reanalyzing samples from intercomparison studies they have previously participated in.

Bidragsytere

Tina Bryntesen

  • Tilknyttet:
    Forfatter
    ved Akkrediterte analysetjenester ved Norsk institutt for vannforskning
1 - 1 av 1