Cristin-resultat-ID: 1859712
Sist endret: 6. juli 2021, 11:23
NVI-rapporteringsår: 2021
Resultat
Vitenskapelig artikkel
2021

Rapid determination of thyroid hormones in blood plasma from Glaucous gulls and Baikal seals by HybridSPE®-LC-MS/MS

Bidragsytere:
  • Kristine Vike-Jonas
  • Susana Villa Gonzalez
  • Åse-Karen Mortensen
  • Tomasz Maciej Ciesielski
  • Julia Farkas
  • Vishwesh Venkatraman
  • mfl.

Tidsskrift

Journal of chromatography. B
ISSN 1570-0232
e-ISSN 1873-376X
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2021
Publisert online: 2020
Volum: 1162
Sider: 1 - 9
Artikkelnummer: 122447
Open Access

Importkilder

Scopus-ID: 2-s2.0-85097341850

Beskrivelse Beskrivelse

Tittel

Rapid determination of thyroid hormones in blood plasma from Glaucous gulls and Baikal seals by HybridSPE®-LC-MS/MS

Sammendrag

A rapid hybrid solid phase extraction (HybridSPE®) protocol tailored to liquid chromatography–electrospray ionization tandem mass spectrometry (LC–ESI–MS/MS) analysis, was developed for the determination of four thyroid hormones, L-Thyroxine (T4), 3,3′,5-triiodo-L-thyronine (T3), 3,3′,5′-triiodo-L-thyronine (rT3) and 3,3′-diiodo-L-thyronine (T2) in blood plasma from Glaucous gulls (Larus hyperboreus) and Baikal seals (Phoca sibirica). The use of target analyte specific 13C internal standards allowed quantification to be performed through the standard solvent calibration curves and alleviated the need to perform quantification with matrix match curves. The relative recoveries were 100.0–110.1 % for T4, 99.1–102.2 % for T3, 100.5–108.0 % for rT3, and 100.5–104.6 % for T2. The matrix effects ranged from −1.52 to −6.10 %, demonstrating minor signal suppression during analysis. The method intra-day precision (method repeatability, RSD %, N = 5, k = 1 day) and inter-day precision (method reproducibility, RSD %, N = 10, k = 2 days) at the 1 ng/mL concentration of fortification were 8.54–15.4 % and 15.4–24.8 %, respectively, indicating acceptable chromatographic peak stabilities for all target THs even at trace level concentrations. The method limit of detection (LOD) for T4, T3, rT3 and T2 was 0.17, 0.16, 0.30 and 0.17 ng/mL, respectively. The HybridSPE® protocol was simple and rapid (

Bidragsytere

Kristine Vike-Jonas

  • Tilknyttet:
    Forfatter
    ved Institutt for kjemi ved Norges teknisk-naturvitenskapelige universitet

Susana Villa Gonzalez

  • Tilknyttet:
    Forfatter
    ved Institutt for kjemi ved Norges teknisk-naturvitenskapelige universitet

Åse-Karen Mortensen

  • Tilknyttet:
    Forfatter
    ved Institutt for biologi ved Norges teknisk-naturvitenskapelige universitet

Tomasz Maciej Ciesielski

  • Tilknyttet:
    Forfatter
    ved Institutt for biologi ved Norges teknisk-naturvitenskapelige universitet

Julia Farkas

  • Tilknyttet:
    Forfatter
    ved Klima og miljø ved SINTEF Ocean
1 - 5 av 9 | Neste | Siste »