The potential impact of the small-scale ejector on the R744 transcritical refrigeration system

Bidragsytere:
  • Anas F.A. Elbarghthi
  • Vaclav Dvorak
  • Armin Hafner og
  • Krzysztof Banasiak

Tidsskrift

Energy Conversion and Management
ISSN 0196-8904
e-ISSN 1879-2227
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2021
Publisert online: 2021
Trykket: 2021
Volum: 249
Artikkelnummer: 114860

Importkilder

Scopus-ID: 2-s2.0-85117708006

Beskrivelse Beskrivelse

Tittel

The potential impact of the small-scale ejector on the R744 transcritical refrigeration system

Sammendrag

The evident adverse effects of climate change and the consequences of global warming has left an exigent circumstance requiring crucial actions on the applications and technology of refrigeration and air conditioning systems as it concerns its tremendous indirect contributions to greenhouse gas emissions. This field has witnessed steady expansion in recent times. The attendant high-grade energy consumption calls for pragmatic approaches to developing innovative technologies aimed at energy management and finding measures to curb global warming. This current study intends to illustrate the impact of implementing a small-size ejector profile on the R744 transcritical refrigeration system to improve the system performance by recovering some expansion work and reduce power consumption. The ejector-supported system was compared with the parallel compression concept as the baseline system and carried out at different pressure lift and exit gas cooler properties. The result indicated a COP and exergy efficiency improvement up to 2.05% and 1.92% for the set conditions respectively, while the COP could be improved to the highest of 11.22% when the system cooling load is at minimum. Moreover, the ejector played a vital role in the system input power, where up to 3.46% of the energy consumption was reduced at subcritical heat rejection conditions. Operating the system with an ejector at a lower cooling capacity allows a further 18% reduction in overall power consumption. In addition, the exergy analysis revealed a noticeable lack of total system exergy destruction by deploying the ejector in parallel with the high-pressure valve, which recovered 21% of the expansion work and saved 46% of the HPV exergy losses. Furthermore, the result exhibited a maximum system exergy loss of 7.8% at the set condition and a maximum of 13.2% total system exergy destruction rate recovered by the ejector, which depends on the cooling load.

Bidragsytere

Anas F.A. Elbarghthi

  • Tilknyttet:
    Forfatter
    ved Technical University of Liberec

Vaclav Dvorak

  • Tilknyttet:
    Forfatter
    ved Technical University of Liberec
Aktiv cristin-person

Armin Hafner

  • Tilknyttet:
    Forfatter
    ved Institutt for energi- og prosessteknikk ved Norges teknisk-naturvitenskapelige universitet

Krzysztof Banasiak

  • Tilknyttet:
    Forfatter
    ved Termisk energi ved SINTEF Energi AS
1 - 4 av 4