Cristin-resultat-ID: 2061441
Sist endret: 14. oktober 2022, 11:15
NVI-rapporteringsår: 2022
Resultat
Vitenskapelig Kapittel/Artikkel/Konferanseartikkel
2022

Performance analysis of high temperature heat pumps and thermal energy storages for a dairy

Bidragsytere:
  • Marcel Ulrich Ahrens
  • August Brækken
  • Sverre Stefanussen Foslie
  • Ole Marius Moen
  • Kim Andre Lovas
  • Michael Bantle
  • mfl.

Bok

15th IIR-Gustav Lorentzen Conference on Natural Refrigerants - GL2022 - Proceedings - Trondheim, Norway, June 13-15th 2022
ISBN:
  • 978-2-36215-045-6

Utgiver

International Institute of Refrigeration
NVI-nivå 1

Serie

Science et technique du froid
ISSN 0151-1637
e-ISSN 1766-0408
NVI-nivå 1

Om resultatet

Vitenskapelig Kapittel/Artikkel/Konferanseartikkel
Publiseringsår: 2022
Hefte: 2022-15
ISBN:
  • 978-2-36215-045-6
Open Access

Klassifisering

Fagfelt (NPI)

Fagfelt: Energi
- Fagområde: Realfag og teknologi

Beskrivelse Beskrivelse

Tittel

Performance analysis of high temperature heat pumps and thermal energy storages for a dairy

Sammendrag

This paper analyses the performance of the integrated energy system of an existing dairy in Bergen, Norway. The investigated dairy has an innovative solution for the thermal process supply by using only heat pumps and thermal energy storage to cover all temperature levels of the existing heating and cooling demand. The aim of the study was to determine the energy consumption and system performance for one winter week and one summer week and compare these results against each other. To evaluate the performance, a comprehensive energy analysis was carried out based on the available process data. The results show for a comparatively energy-intensive week in February that the integrated energy system covers the existing demand and can compensate for demand peaks, with a waste heat recovery rate of over 95% for the process. The chillers and heat pumps achieved high COPs in the range of 4.2 to 5.9, while the overall system achieved a total COP of 4.1. A comparative week in June was then investigated and compared with the results of the operating week in February. Due to higher building cooling demands and lower building heating demands, the demand for dry cooling was significantly increased in the summer, whereas the need for electric heating and district heating was reduced. The achieved COPs in the range of 4.2 to 5.7 were similar in the summer week, meaning that the energy system functions well in different climatic conditions. Based on the results of this study, the performance of the system under different conditions was evaluated and the impact on power consumption and potential use for other climatic regions was discussed.

Bidragsytere

Marcel Ulrich Ahrens

  • Tilknyttet:
    Forfatter
    ved Institutt for energi- og prosessteknikk ved Norges teknisk-naturvitenskapelige universitet

August Brækken

  • Tilknyttet:
    Forfatter
    ved Termisk energi ved SINTEF Energi AS

Sverre Stefanussen Foslie

  • Tilknyttet:
    Forfatter
    ved Termisk energi ved SINTEF Energi AS

Ole Marius Moen

  • Tilknyttet:
    Forfatter
    ved Termisk energi ved SINTEF Energi AS

Kim Andre Lovas

  • Tilknyttet:
    Forfatter
    ved Tine Norske Meierier BA
1 - 5 av 8 | Neste | Siste »

Resultatet er en del av Resultatet er en del av

15th IIR-Gustav Lorentzen Conference on Natural Refrigerants - GL2022 - Proceedings - Trondheim, Norway, June 13-15th 2022.

IIR, .. 2022, International Institute of Refrigeration. Vitenskapelig antologi/Konferanseserie
1 - 1 av 1