Cristin-resultat-ID: 2101935
Sist endret: 9. oktober 2023, 10:38
NVI-rapporteringsår: 2023
Resultat
Vitenskapelig artikkel
2023

Thin-film composite mixed-matrix membrane with irregular micron-sized UTSA-16 for outstanding gas separation performance

Bidragsytere:
  • Hyo Jun Min
  • Miso Kang
  • Youn-Sang Bae
  • Richard Blom
  • Carlos Adolfo Grande og
  • Jong Hak Kim

Tidsskrift

Journal of Membrane Science
ISSN 0376-7388
e-ISSN 1873-3123
NVI-nivå 2

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2023
Publisert online: 2022
Trykket: 2023
Volum: 669
Artikkelnummer: 121295

Importkilder

Scopus-ID: 2-s2.0-85144953244

Beskrivelse Beskrivelse

Tittel

Thin-film composite mixed-matrix membrane with irregular micron-sized UTSA-16 for outstanding gas separation performance

Sammendrag

Low-cost, micron-sized particles still pose a barrier to their use in thin-film composite mixed-matrix membranes (TFC-MMMs) owing to their poor interfacial contact with the polymer matrix. Also, the particles are too large to be fabricated into the submicron-thick membranes. Herein, we report high-performing, TFC-MMMs based on a CO2-philic comb copolymer, poly (tetrahydrofurfuryl methacrylate)–co–poly (poly (oxyethylene methacrylate)) (PTO), and an irregular, micron-sized, CO2-selective metal-organic framework (MOF), UTSA-16. The PTO comb copolymer matrix exhibited excellent film-forming ability, adhesion properties and showed a good gas separating performance. The PTO comb copolymer also enhanced the dispersibility of UTSA-16 in an environment-friendly solvent mixture (i.e., ethanol/water), which did not adversely damage the underlying porous polymeric support. Despite the micron-scale particle size of UTSA-16, PTO copolymer completely covered the surface of UTSA-16 via strong interactions without any deep pore infiltration and exhibited excellent interfacial contact properties. Consequently, defect-free TFC-MMMs with a polymer thickness of 300 nm were successfully prepared on the porous support. The TFC-MMM with 10% filler loading exhibited excellent CO2 permeance and selectivity, i.e., CO2 permeance of 1070 GPU, CO2/N2 selectivity of 41.0, CO2/CH4 selectivity of 17.2, outperforming the TFC-MMMs prepared with commercially available Pebax. All PTO-based MMMs, with the exception of the low content of UTSA-16 (5%), exceeded the gas separation performance required for post-combustion CO2 capture process.

Bidragsytere

Hyo Jun Min

  • Tilknyttet:
    Forfatter
    ved Yonsei University

Miso Kang

  • Tilknyttet:
    Forfatter
    ved Yonsei University

Youn-Sang Bae

  • Tilknyttet:
    Forfatter
    ved Yonsei University

Richard Blom

  • Tilknyttet:
    Forfatter
    ved Prosessteknologi ved SINTEF AS

Carlos Adolfo Grande

  • Tilknyttet:
    Forfatter
    ved Prosessteknologi ved SINTEF AS
1 - 5 av 6 | Neste | Siste »