Purpose: To determine the effect of femtosecond laser cutting parameters on small-incision lenticule extraction (SMILE) results by evaluating cap thickness, interface light scattering, and visual and refractive outcomes.
Setting: SynsLaser Clinic, Oslo, Norway.
Design: Retrospective.
Methods: 58 right eyes treated with SMILE using a programmed cap thickness of 130 μm were divided into 2 groups according to laser settings: Group 1: 165 nJ pulse energy and 4.5 μm spot separation (n = 36); Group 2: 125 nJ pulse energy and 4.2 μm spot separation (n = 22). The cap thickness was measured within the central 5 mm of the horizontal meridian using spectral-domain optical coherence tomography. Postoperative interface light scattering was graded based on the percentage area showing light scattering: 0: no scattering; 1: ≤25%; 2: 26% to 50%; 3: 51% to 75%; and 4: >75%.
Results: At 3 months postoperatively, cap thickness was 138.9 ± 6.2 μm in Group 1 and 149.4 ± 3.5 μm in Group 2 (P