Cristin-resultat-ID: 2140666
Sist endret: 12. januar 2024, 09:11
NVI-rapporteringsår: 2023
Resultat
Vitenskapelig artikkel
2023

Power oscillation damping method suitable for network reconfigurations based on converter interfaced generation and combined use of active and reactive powers

Bidragsytere:
  • Njegos Jankovic
  • Javier Roldan-Perez
  • Milan Prodanovic
  • Jon Are Wold Suul
  • Salvatore D'Arco og
  • Luis Rouco Rodriguez

Tidsskrift

International Journal of Electrical Power & Energy Systems
ISSN 0142-0615
e-ISSN 1879-3517
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2023
Publisert online: 2023
Trykket: 2023
Volum: 149
Artikkelnummer: 109010
Open Access

Importkilder

Scopus-ID: 2-s2.0-85150440668

Beskrivelse Beskrivelse

Tittel

Power oscillation damping method suitable for network reconfigurations based on converter interfaced generation and combined use of active and reactive powers

Sammendrag

Power system stabilisers (PSSs) are commonly used in synchronous generators for damping low-frequency oscillations. However, many of these machines have been replaced by converter-interfaced generators (CIGs), such as those used in solar power plants. This means that CIG-based power plants should also contribute to oscillation damping. Moreover, CIGs may use both active and reactive power for power oscillation damping (POD). However, their combined use has been seldom studied in the literature. Moreover, only a few articles have addressed the adaption of POD controllers when the power system changes (e.g., after a fault). In this paper, a POD controller for CIG-based power plants is proposed that is suitable for operation in power systems exposed to reconfiguration. This controller takes advantage of both active and reactive power injection to maximise the damping of the power system. This controller is based only on local measurements so communication systems are not required. Theoretical developments were validated in a laboratory using real power converters including a 75 kVA grid emulator where the two-area benchmark model is emulated and four 15 kVA CIGs operating in parallel connection. The applicability of the proposed controller was also explored for the IEEE 39-bus system.

Bidragsytere

Njegos Jankovic

  • Tilknyttet:
    Forfatter
    ved Spania

Javier Roldan-Perez

  • Tilknyttet:
    Forfatter
    ved Spania

Milan Prodanovic

  • Tilknyttet:
    Forfatter
    ved Spania

Jon Are Wold Suul

  • Tilknyttet:
    Forfatter
    ved Energisystemer ved SINTEF Energi AS

Salvatore D'Arco

  • Tilknyttet:
    Forfatter
    ved Energisystemer ved SINTEF Energi AS
1 - 5 av 6 | Neste | Siste »