Analysis of Partial Discharge Activity for Multi-Stress Accelerated Aged Stator Bars

Bidragsytere:
  • Birender Singh
  • Frank Mauseth
  • Espen Eberg og
  • Emre Kantar

Bok

2023 IEEE Electrical Insulation Conference - EIC
ISBN:
  • 978-1-6654-9341-3

Utgiver

IEEE (Institute of Electrical and Electronics Engineers)
NVI-nivå 1

Om resultatet

Vitenskapelig Kapittel/Artikkel/Konferanseartikkel
Publiseringsår: 2023
ISBN:
  • 978-1-6654-9341-3

Klassifisering

Fagfelt (NPI)

Fagfelt: Elektrofag
- Fagområde: Realfag og teknologi

Beskrivelse Beskrivelse

Tittel

Analysis of Partial Discharge Activity for Multi-Stress Accelerated Aged Stator Bars

Sammendrag

During intermittent operation of power stations, the stator mainwall insulation is subjected to increased thermomechanical stress which may eventually lead to stator insulation failure. Thermal load cycling and voltage stress test, i.e., multi-stress testing is used in this work to investigate the deterioration of the stator winding insulation. To perform multistress testing on service-aged, back-up and dummy coils (each comprises two coils), a test setup was created in the lab to subject the stator bars to stresses relevant to service conditions. Partial discharge (PD) measurements were conducted to monitor the conditions of the main wall insulation. Here, on-cycle / off-cycle PD diagnosis were applied to examine the stator winding insulation under multi-stress conditions. The coils were subjected to 200 thermal load cycles where each cycle stresses them for 50 min from 40°C to 110°C and then cools down back to 40°C in 45 min. Also, the service aged, and back-up coils were stressed 1.5 times their nominal phase to ground voltage. After every fifty thermal cycles, the stress voltage was reduced to nominal voltage to conduct PD measurements on service-aged and back-up coils. The PD inception voltage, dielectric losses (tan δ), and average partial discharge (Q IEC ) obtained under multi-stress conditions were discussed and it was found that thermal cycling exhibits signs of aging in the stator winding insulating systems. © 2023 IEEE.

Bidragsytere

Birender Singh

  • Tilknyttet:
    Forfatter
    ved Institutt for elektrisk energi ved Norges teknisk-naturvitenskapelige universitet

Frank Mauseth

  • Tilknyttet:
    Forfatter
    ved Institutt for elektrisk energi ved Norges teknisk-naturvitenskapelige universitet

Espen Eberg

  • Tilknyttet:
    Forfatter
    ved Elkraftteknologi ved SINTEF Energi AS

Emre Kantar

  • Tilknyttet:
    Forfatter
    ved Elkraftteknologi ved SINTEF Energi AS
1 - 4 av 4

Resultatet er en del av Resultatet er en del av

2023 IEEE Electrical Insulation Conference - EIC.

EIC 2023, .. 2023, IEEE (Institute of Electrical and Electronics Engineers). Vitenskapelig antologi/Konferanseserie
1 - 1 av 1