Grid Turbulence Measurements with an Acoustic Doppler Current Profiler

Bidragsytere:
  • Trygve Kvåle Løken
  • David Roger Lande-Sudall
  • Atle Jensen og
  • Jean Rabault

Tidsskrift

Fluids
ISSN 2311-5521
e-ISSN 2311-5521
NVI-nivå 1

Om resultatet

Vitenskapelig artikkel
Publiseringsår: 2024
Publisert online: 2024
Trykket: 2024
Volum: 9
Hefte: 3
Sider: 1 - 14
Artikkelnummer: 60
Open Access

Importkilder

Scopus-ID: 2-s2.0-85188723506

Klassifisering

Vitenskapsdisipliner

Mekaniske og strømningstekniske fag • Matematikk

Emneord

Turbulens

Beskrivelse Beskrivelse

Tittel

Grid Turbulence Measurements with an Acoustic Doppler Current Profiler

Sammendrag

The motivation for this study is to investigate the abilities and limitations of a Nortek Signature1000 acoustic Doppler current profiler (ADCP) regarding fine-scale turbulence measurements. Current profilers offer the advantage of gaining more coherent measurement data than available with point acoustic measurements, and it is desirable to exploit this property in laboratory and field applications. The ADCP was tested in a towing tank, where turbulence was generated from a grid towed under controlled conditions. Grid-induced turbulence is a well-studied phenomenon and a good approximation for isotropic turbulence. Several previous experiments are available for comparison and there are developed theories within the topic. In the present experiments, a Nortek Vectrino acoustic Doppler velocimeter (ADV), which is an established instrument for turbulence measurements, was applied to validate the ADCP. It was found that the mean flow measured with the ADCP was accurate within 4% of the ADV. The turbulent variance was reasonably well resolved by the ADCP when large grid bars were towed at a high speed, but largely overestimated for lower towing speed and smaller grid bars. The effective cutoff frequency and turbulent eddy size were characterized experimentally, which provides detailed guidelines for when the ADCP data can be trusted and will allow future experimentalists to decide a priori if the Nortek Signature can be used in their setup. We conclude that the ADCP is not suitable for resolving turbulent spectra in a small-scale grid-induced flow due to the intrinsic Doppler noise and the low spatial and temporal sample resolution relative to the turbulent scales.

Bidragsytere

Trygve Kvåle Løken

  • Tilknyttet:
    Forfatter
    ved Fakultet for lærerutdanning og kunst- og kulturfag ved Nord universitet

David Roger Lande-Sudall

  • Tilknyttet:
    Forfatter
    ved Institutt for maskin- og marinfag ved Høgskulen på Vestlandet

Atle Jensen

  • Tilknyttet:
    Forfatter
    ved Mekanikk ved Universitetet i Oslo

Jean Rabault

  • Tilknyttet:
    Forfatter
    ved Meteorologisk institutt
1 - 4 av 4